Zoeller 10-1244, Simplex Explosion Proof Control Panel With Alarm, Control, 200/230/460 Volts, 3 Phase, 4X Enclosure, 1.6 to 2.5 Amps
SKU #: 10-1244
Brand: Zoeller
Available For Order! ((Usually Ships 3-5 Days))This product is direct shipped from the manufacturer to our distribution center where it is checked, packaged and processed by our quality control team. The estimated shipping time of 7 to 21 days may vary depending on the manufacturer stock, backlogs or delays. To confirm manufacturer lead time for this item, call our Pump Products sales representatives at 800-429-0800 between the hours of 7:30 A.M. - 4:30 P.M. E.S.T.
Some manufacturers require internet retailers to display a price at or above manufacturers established MAP ("Minimum Advertised Price").
Since our price for this product is lower than MAP, the manufacturer does not allow us to display our lowest price until you place the product in the shopping cart. This allows us to continue offering our lowest prices while staying consistent with product manufacturers policy.
This process does not require you to purchase the product - it can be easily removed from shopping cart if needed.
Mon-Fri 7:00 am to 6:00 pm EST
Sat 8:00 am to 4:30 pm EST
Call Toll Free: 800-429-0800
"Ask Inspector PumpHead"
Our Friendly Staff At PumpProducts.com Can Assist You In Placing Your Order.
Sales Representatives Available!
Mon-Fri 7:00 am to 6:00 pm EST
Sat 8:00 am to 4:30 pm EST
This intrinsically-safe control panel is used on pump applications defined as hazardous duty locations. Lift stations in some regions fall under this classification. The intrinsically-safe panel, in conjunction with an explosion-proof pump, will provide a system that will not allow ignition of the explosive gases. The purpose of the control panel is to cycle a pump automatically. Each panel comes standard with pump run light(s), a high water audible and visual alarm, seal fail indicator(s), and a UL listing. All panels come standard with a NEMA 4X rating for indoor or outdoor use.
This panel MUST NOT be in the space classified as needing explosion-proof equipment. Special fittings that either prevent the passage of hot gases in the case of an explosion in a Class 1 area or the passage of a combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and 502-5) are required. A qualified electrician must install all electrical systems. National Electrical Code (NEC) articles 500 through 503 explain in detail the requirements for the installation of wiring or electrical equipment in hazardous locations. These articles, along with any other applicable regulations, local governing inspection authorities, insurance representatives and qualified engineering/technical assistance, should be your guides to the installation of wiring or electrical equipment in any hazardous or potentially hazardous locations.
Features
1.6 to 2.5 Amps
For use on hazardous location pump model GX282
Intrinsically-safe relays
NEMA 4X enclosure
Top-mounted alarm light
Hands-off-auto toggle switch for each pump
Thermal cutouts
Meets UL standards
Alarm horn with silence switch
Magnetic motor contractor
Lockable latch
Auxiliary dry contact/high water alarm
Circuit breaker pump disconnect
3 or 4 variable float switch control operation
The use of off-the-shelf components provide for relatively easy field maintenance and repair
Green pump run pilot light for each pump
Seal fail indicator light(s)
Dimensions (H x W x D): 16" x 14" x 6"
2 year warranty
Note: Intrinsically-Safe control panels are NOT to be installed in a hazardous location.